The 9-Point Pre-Job Checklist I Run Before Every Emergency Thermal Inspection
-
1. Confirm the lens and field of view match the target
-
2. Pack two charged batteries, not one
-
3. Verify sensor calibration status — and do a quick reference check
-
4. Update firmware and confirm image format
-
5. Test the full image export and reporting pipeline
-
6. Measure your mounting points before you drive off
-
7. If you're using a phone-attached camera, test the connection and charging
-
8. Set emissivity and reflected temperature to your shop's standard values
-
9. Confirm the deliverable format with the client before you leave
-
Common mistakes to watch for
I'm the guy who gets the call when a client says, "We need a thermal inspection done by tomorrow morning." In my role coordinating emergency field service for an industrial inspection company, I've handled 200+ rush orders over seven years, including same-day turnarounds for manufacturing and facilities clients. Last quarter alone we processed 47 rush orders with a 95% on-time delivery rate.
That track record didn't come from being fast. It came from checking things before we left the shop.
This checklist is for any technician or team lead who needs to deploy a handheld thermal imaging camera — or a phone-attached unit — on short notice. It takes about 20 minutes to run through. It has saved us from at least four would-be disasters in the last two years, including one where a missing lens adapter would have meant a 3-hour round trip and a $4,000 project delay.
Here's the 9-point pre-job checklist I use.
1. Confirm the lens and field of view match the target
This sounds obvious. It isn't. Most FLIR handheld thermal imaging cameras accept interchangeable lenses (25°, 45°, even 6° telephoto for long-range work). Grabbing the wrong one is an easy mistake when you're loading the truck in a hurry.
Check the job specification sheet: target size, distance, and required spot size. A 45° lens is great for low-voltage panel scans up close. It's borderline useless for scanning a 40-foot overhead conveyor from the floor.
I keep a printed lens-to-application cheat sheet taped inside our camera case. Takes 30 seconds to double-check. I skipped this once in 2023 and ended up borrowing a lens from a competitor's field team (awkward).
2. Pack two charged batteries, not one
Standard practice for most field techs is one battery in the camera and a spare in the bag. For emergency jobs, I bring two spares. Cold environments drain lithium-ion packs faster than the spec sheet suggests, and if you're working a 6-hour site visit in January, that "10-hour battery" might give you four.
This is one of those things that's so basic it feels silly to write down (note to self: still had to replace a dead battery mid-inspection last winter). Battery failure is the most common reason our techs call the office during a rush job. It's also the most preventable.
3. Verify sensor calibration status — and do a quick reference check
Here's where sensors test & calibration becomes a real workflow issue, not just a compliance checkbox.
Check the camera's last calibration date. For critical inspection work — especially anything tied to safety or regulatory reporting — we require calibration within the last 12 months. If your FLIR camera or any handheld unit is past that window, flag it before you leave.
Then do a quick ambient reference check: point the camera at a known-temperature surface (a blackbody reference source if you have one, or a calibrated surface thermometer reading) and confirm the reading is within your acceptable tolerance. It takes two minutes.
I'm not 100% sure how other shops handle this, but we started this step after a camera went out of tolerance on a job last year. The potential liability alone was enough to make it permanent policy.
4. Update firmware and confirm image format
Firmware updates fix sensor bugs, improve image processing, and occasionally change file formats or metadata structures. If your reporting software expects radiometric JPEGs and the latest firmware defaults to a different export format, you'll find out at the worst possible moment — usually when the client is standing behind you.
Check for updates the week of any rush job. Apply them. Then take one test image and export it through your reporting workflow before you leave the shop.
In my first year, I made the classic rookie mistake: assumed the camera worked out of the box. Cost me two hours of re-exporting images because the firmware on a new unit hadn't been updated and stored files in a format our software didn't recognize.
5. Test the full image export and reporting pipeline
This is the step most people skip. They check the camera, the battery, the lens — and then discover at 10 p.m. that the report template is locked, or the cloud folder doesn't sync, or the USB-C adapter is missing.
Run one full-cycle test: capture a test image, transfer it to your laptop or tablet, open it in your reporting tool, drop it into the template, export a PDF. Then delete it.
The whole thing takes maybe 4 minutes. It prevents the 45-minute panic that happens when you're already tired and the deadline is close.
6. Measure your mounting points before you drive off
Not every inspection is handheld. A lot of rush jobs involve temporary or semi-permanent camera mounting — tripods, pole mounts, machine guards, or custom brackets. If the mount doesn't fit, the camera doesn't go up, and the inspection doesn't happen.
This is where a decent caliper earns its keep. I keep a Mitutoyo 500-197-30 digital caliper in my inspection bag. It measures ID, OD, depth, and step — covers basically everything I need for mount verification. It's not exotic, but it's consistent, and the battery lasts forever.
Before you leave, measure the actual mounting surface or bracket opening at the site (if you have photos or past measurements) and compare to your mounting hardware. If you're installing a camera enclosure or pan-tilt unit, a few millimeters of mismatch can mean a bracket that wobbles just enough to blur long-exposure thermal images.
I've seen techs drive out with a tripod that didn't match the threaded insert. Doing this check at the shop takes under a minute. Doing it at the client's site adds an hour you probably don't have.
7. If you're using a phone-attached camera, test the connection and charging
Phone thermal cameras — like the Cat S62 Pro (which uses a FLIR Lepton sensor) or FLIR One attachments — are genuinely useful for tight spaces and quick spot checks. They are not a replacement for a dedicated handheld unit on critical inspections, but they're a solid backup or secondary tool.
If one is part of your kit, check three things: the connector is clean and secure, the companion app is updated, and the phone has enough charge to run the camera module for the duration of the visit (the FLIR module draws noticeable power — plan for it).
We've had two instances where a phone attachment was the only working camera on-site. Both times, the tech had charged the phone and tested the connection before leaving. That's the only reason the job got done.
8. Set emissivity and reflected temperature to your shop's standard values
Different materials need different emissivity settings. Bare metal is low (around 0.1-0.2). Painted surfaces and most electrical insulation run higher (0.85-0.95). If you leave the camera on default emissivity and scan a shiny copper busbar, your temperature reading will be wrong — sometimes by 20°F or more.
Most shops have a standard operating procedure for emissivity values by material type. Load those settings before you leave. If your procedure doesn't exist yet, build one this week. Two minutes of setup prevents an embarrassing report rewrite.
One more note: if your team uses both FLIR and Fluke thermal cameras (many do), confirm which unit the SOP was written for. Emissivity tables are often brand-specific, and the default values don't always transfer cleanly. This is less about "which brand is better" and more about keeping your reference settings consistent across whichever tool your team actually grabs at 6 a.m.
9. Confirm the deliverable format with the client before you leave
This is the step that saves the most rework, and it has nothing to do with the camera.
Does the client want a PDF report, a raw data export, annotated images, or all three? Do they need a specific naming convention? Is there a template you haven't seen before? A 90-second phone call or email before you head out prevents a 2-hour post-processing session at 11 p.m.
We learned this the hard way in 2023. We delivered a full thermal report in our standard format, and the client's procurement team rejected it because it didn't match their internal template (which they'd forgotten to send). We redid the export. It cost us a full evening. Now, we ask first — every time.
Common mistakes to watch for
Skipping the calibration check. It's the easiest step to skip when you're in a hurry. It's also the one most likely to cause a rejected report or a liability issue. Don't skip it.
Assuming lens torque isn't important. Interchangeable lenses need to be snug — but not over-tightened. A loose lens creates blurry or offset images that are hard to correct in post. Check the seal, check the lock ring, and verify with a quick test image.
Not testing the full export pipeline. Every single time we've had a "the files won't open" problem, it was discovered on-site. Test the pipeline at the shop.
Forgetting that the client's deadline is not your deadline. The job might be due Friday, but the client might need the images Thursday night for a board meeting. Confirm the actual cutoff time, not just the delivery date.
The bottom line: 5 minutes of verification beats 5 days of correction. That's not a slogan — it's what our project records actually show. The checklist takes less time than a coffee break. The mistakes it prevents take hours to fix.
Run it before your next rush job. You'll notice the difference by about step four.